2 Way Angle Valve Vs 3 Way Angle Valve

The SED Angle Seat Valve is composed of a 2/2-way angle seat valve body and a pneumatically operated piston actuator, which is mounted with a stainless steel adaption to the valve body. Depending on the size, the actuators are made of plastic. High Pressure (coned & threaded) type connections for 1/8 in., 1/4 in., 3/8 in., 9/16 in. Non-rotating tip stems are standard for on-off service and ensure long life on valve seats. Glands and collars for tubing are supplied with each valve. Parker 1/2' 2-Way Normally Closed Angle Body Valves provide operating pressures up to 232 psi for air, inert gasses and liquids, or 130 psi for steam with flow factors of 5.5 Cv. They can handle corrosive solutions and temperatures up to 356 F.

2 way angle valve vs 3 way angle valve coupling

2-way valves are pretty simple and straight-forward. A 2-way valve is any type of valve with two ports: an inlet and an outlet port, typically labeled “A” and “AB” respectively. 2-way valves are used in many applications, from basic on/off to more complex variable flow applications with pumps and VFDs. The type of valve you need for an application depends on the amount of flow, the degree of control, shut-off, and pressure drops over the valve.

3-way valves have, yes, three ports, labeled “A”, “B”, and “AB”. Port “AB” is common to the “A” or “B” port. 3-way valves are commonly found in constant flow/volume pumping systems and can be either mixing or diverting valves. 3-way valves can be piped in the supply or return. If in the supply, then a diverting valve is used. If piped in the return, a mixing valve is used. Ball valves can be piped to be mixing or diverting, but globe valves require different bodies for mixing or diverting.

2 Way Angle Valve Vs 3 Way Angle Valve

Mixing applications have the 3-way valve configured with two inputs from the supply piping and one output to the return piping, thus mixing together two inputs before sending it out. Mixing valves are most commonly used with modulating control but can be on/off.

Diverting applications have the 3-way valve configured with one input from the supply side and two outputs to the return piping. In general, diverting valves are more expensive than mixing valves.

Make sure to watch this short easy to understand video on control signals .

Every valve has some sort of control actuator and control signal. It could be on/off, floating, or a proportional signal. Click here and watch this easy to follow, short, HVAC Tech School video and learn the easy way about HVAC control signals.

2 Way Angle Valve Vs 3 Way Angle Valve

  • belimo, control valve, honeywell, hvac controls, johnson controls